Page 5
SERVICE (cont.)
RELAY (BREWERS W/BREW LOCKOUT)
B
9
6
8
5
7
B
6
9
8
5
A
1
4
7
2
3
A
1
4
2
3
10/08V, 10/40V, 08V, 380V, 440V AND 40V 
MODELS PRIOR TO #U300004095
30V MODELS #U300004095 AND UP
FIG.19 RELAY TERMINALS
P1739
RED from
Main Harness
BLU from
Brew Timer
BLK to Control
Thermostat
BLU to Start
Switch
BLU from
Brew Timer
BLK from
Main Harness
RED to Control
Thermostat
BLU from
Start Switch
Removal and Replacement:
1.  Disconnect the wires from the relay.
.  For 10/08V, 10/40V, 08V, 380V, 440V and 
40V models prior to #U300004095 remove the 
#6-3 screw securing the relay to the relay mount-
ing bracket. For 30V models #U300004095 and 
up, remove the two screws securing the relay to 
the relay mounting bracket.
3.  Remove relay and discard.
4.  For  10/08V,10/40V,  08V,  380V,  440V  and 
40V models prior to #U300004095, install new 
relay on relay mounting bracket and secure with 
a #6-3 screw. For 30V models #U300004095 
and up, install new relay on relay mounting bracket 
and secure with two #6-3 screws.
5.  Refer to Fig. 19 and reconnect the wires.
10060  080900