Avaya P550 Guía De Referencia
Port
12-32
Cajun P550/P220 Command Line Interface Reference Guide
. * *
Enable or disable remote fault detections for gigabit ports.
Command Syntax
Table 12-23.
Parameters, Keywords, Arguments
This example enables remote fault detection in gigabit ports 1 and 2 on the module in
slot 3 of a Cajun P550 or P550R.
slot 3 of a Cajun P550 or P550R.
Cajun(configure)# set port remote-fault-detect 3/1,3/2 enable
Port remote fault detection enable set: 3/1,3/2.
This example disables remote fault detection in the gigabit ports G2 through G4 of a
Cajun P220G.
Cajun P220G.
Cajun(configure)# set port remote-fault-detect G2-G4 disable
Port remote fault detection disable set: G2,G3,G4.
To Enable:
set port remote-fault-detect
{<mod-num>|<mod-port-range>}
[...,{<mod-num>|<mod-port-range>}]{disable|enable}
Name
Definition
mod-num
Specifies the number of the module where the ability to
detect remote link errors for each gigabit port on the
module is to be set.
detect remote link errors for each gigabit port on the
module is to be set.
mod-port-range
Specifies a port or a range of gigabit ports whose
ability to detect remote link errors are enabled or
disabled.
ability to detect remote link errors are enabled or
disabled.
disable|enable
Disables or enables the remote fault detection
capability for the specified gigabit ports.