Avaya P550 Guia De Referência

Página de 595
Port
12-32
 Cajun P550/P220 Command Line Interface Reference Guide
 . * *
   
Enable or disable remote fault detections for gigabit ports.
Command Syntax
Table 12-23.  
Parameters, Keywords, Arguments
 
This example enables remote fault detection in gigabit ports 1 and 2 on the module in 
slot 3 of a Cajun P550 or P550R.
Cajun(configure)# set port remote-fault-detect 3/1,3/2 enable
Port remote fault detection enable set: 3/1,3/2.
This example disables remote fault detection in the gigabit ports G2 through G4 of a 
Cajun P220G.
Cajun(configure)# set port remote-fault-detect G2-G4 disable
Port remote fault detection disable set: G2,G3,G4.
 To Enable:
set port remote-fault-detect 
{<mod-num>|<mod-port-range>}
[...,{<mod-num>|<mod-port-range>}]{disable|enable}
Name
Definition
mod-num
Specifies the number of the module where the ability to 
detect remote link errors for each gigabit port on the 
module is to be set.
mod-port-range
Specifies a port or a range of gigabit ports whose 
ability to detect remote link errors are enabled or 
disabled.
disable|enable
Disables or enables the remote fault detection 
capability for the specified gigabit ports.