Cisco Cisco ONS 15454 SDH Multiservice Provisioning Platform (MSPP) Notas de publicación

Descargar
Página de 18
 
3
Release Notes for Cisco ONS 15454 SDH Release 7.0.1
78-xxxxx-xx
  Caveats
for your release and platform for appropriate troubleshooting procedures. To exit without logging in, 
enter a Control-D (hold down the Control and D keys at the same time) at the Username prompt. To exit 
after logging in, type “logout” at the VxWorks shell prompt.
CSCsd49163
In a Y cable protection group using TXP_MR_10E or TXT_MR_10DME cards the switch time when 
you remove a trunk fibre is sometimes longer than 50 ms. This issue will be resolved in a future release.
CSCsd21294
If you disconnect a subtended shelf from a multishelf node controller, the Communication failure is not 
correctly characterized by the LCD and Fan Tray LEDs of the multishelf node. You can use CTC or TL1 
to get the status of the nodes correctly, however. This issue will be resolved in a future release.
CSCsd22880
The APC regulations when a channel is dropped from an AD4C are not correctly managed. Consider a 
channel dropped from the first CHAN-TX port of an AD4C card. In the CTC > Maintenance > DWDM 
tab the APC Last modification date is never changed; it remains N/A. In any case of span aging 
conditions, the object is always incorrectly referred to the fourth channel of the add/drop card, even if 
that channel is not active. This issue will be resolved in a future release.
CSCsd32197
Four channel Mux/Demux PM counters on CHAN ports (both TX and RX) fail to update after midnight 
in both CTM and TL1. This issue will be resolved in a future release.
CSCsd33369
ALS mode can be set to Auto Restart on a TXP_MR_10G trunk port via TL1 when the TXP_MR_10G 
card is configured for an Ethernet 10G LAN payload. This issue will be resolved in a future release.
CSCsc62845
When you try delete a provisionable patchcord (PPC) from the CTC Provisioning > PPC tab, sometimes 
CTC fails to refresh the screen and the PPC deletion appears to have failed. The workaround is to restart 
into CTC. This issue will be resolved in a future release.
CSCef53317
A traffic hit can occur during a clock reference switch. To see this issue, complete the following steps.
Step 1
Set up two ONS 15454 SDH nodes with STM16 SNCP (call the nodes STM16-1 and STM16-2).
Step 2
Set up two ONS 15454 SDH nodes with MXP_MR_2.5G_10G (call the nodes MXP-1 and MXP-2).
Step 3
Place MXP-1 and MXP-2 in Transparent Termination Mode.
Step 4
Ensure that STM16-1 is connected to MXP-1 client 1.