Cisco Cisco UCS B440 M1 High-Performance Blade Server Guía De Instalación

Descargar
Página de 31
Internal USB connector
Cisco UCS-USBFLSH-S-4GB= is recommended, but if
another USB drive will be used it must be no wider than
.8 inches, and no more than 1.345 inches long in order
to provide needed clearances to install or remove the
USB drive.
2
Hard drive bays
1
CPU 1 and heat sink
4
Battery
3
Diagnostic button
6
DIMM slots
5
CPU 2 and heat sink
8
DIMM slots
7
Adapter card connector (Adapter not shown installed)
10
Modular LOM (shown installed)
9
Use of this server may require an upgrade to the IOM in the chassis. This server only supports third
generation adapter cards, which have features requiring a Cisco 2204 or 2208 IOM, and are not backward
compatible with the Cisco 2104 IOM.
Note
Diagnostics Button and LEDs
At blade start-up, POST diagnostics test the CPUs, DIMMs, HDDs, and adapter cards, and any failure notifications are sent to UCS
Manager. You can view these notifications in the Cisco UCS Manager System Error Log or in the output of the show tech-support
command. If errors are found, an amber diagnostic LED also lights up next to the failed component. During run time, the blade BIOS
and component drivers monitor for hardware faults and will light up the amber diagnostic LED as needed.
LED states are saved, and if you remove the blade from the chassis the LED values will persist for up to 10 minutes. Pressing the
LED diagnostics button on the motherboard causes the LEDs that currently show a component fault to light for up to 30 seconds for
easier component identification. LED fault values are reset when the blade is reinserted into the chassis and booted, and the process
begins from its start.
If DIMM insertion errors are detected, they may cause the blade discovery process to fail and errors will be reported in the server
POST information, which is viewable using the UCS Manager GUI or CLI. DIMMs must be populated according to specific rules.
The rules depend on the blade server model. Refer to the documentation for a specific blade server for those rules.
Faults on the DIMMs or adapter cards also cause the server health LED to light solid amber for minor error conditions or blinking
amber for critical error conditions.
Working Inside the Blade Server
Installing a CMOS Battery
All Cisco UCS blade servers use a CR2032 battery to preserve BIOS settings while the server is not installed in a powered-on chassis.
Cisco supports the industry standard CR2032 battery that is available at most electronics stores.
13