61
Environmental Specifications
The environmental specifications for the 5108 blade chassis are listed in 
Table 30  UCS 5108 Blade Server Environmental Specifications
Parameter
Minimum
Temperature operating
10°C to 35°C (50°F to 95°F)
Temperature nonoperating
-40°C to 65°C (-40°F to 149°F)
Altitude operating
0 to 3, 000 m (0 to 10,000 ft.); maximum ambient temperature decreases 
by 1° per 300 m
Humidity operating
10 to 90%, non-condensing
Humidity nonoperating
5 to 93%, non-condensing
Vibration nonoperating
2.2 Grms, 10 minutes per axis on each of the three axes
Shock operating
Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the 
three axes
Shock nonoperating
Trapezoidal, 25 G, two drops on each of six faces ΔV: 175 inches per second 
each corner on bottom face drop, 90 inches per second each corner on 
other five faces
Safety
UL60 950-1 No. 21CFR1040, CAN/CSA-C22.2 No. 60950-1, IRAM IEC60950-1, 
CB IEC60950-1, EN
60950-1, IEC 60950-1, GOST IEC60950-1, SABS/CB IEC6095-1, CCC*/CB 
GB4943-1995, CNS14336, CB IEC60950-1, AS/NZS 60950-1, GB4943
Emissions
47CFR Part 15 (CFR 47) Class A, AS/NZS CISPR22 Class A, CISPR2 2 Class A, 
EN55022 Class A, ICES003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3, 
KN22 Class A, CNS13438 Class A
Immunity
Verified to comply with EN55024, CISPR 24, KN 61000-4 Series, KN 24
Electrostatic discharge
Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV 
contact discharge without physical damage
Acoustic
Sound power: 68.8 dBA at ambient temperature 23° C measured using 
the Dome Method
GOST MsanPiN 001-96