Caveats
DDTS # CSCdz84149
If a user is logged into CTC as a superuser (or other higher level security type), and then another 
superuser changes the first user's security level to “retrieve” (or another lower level security type) 
without first logging the user out, the lower level user is then still able to perform some actions 
authorized only for the original login security level. For example, a “provisioning” level user demoted 
to “retrieve” level in this manner can still provision and edit MS-SPRings (BLSRs) while logged into the 
current session, though the same user may no longer provision DCCs. To ensure that a user's level is 
changed completely, the superuser must log the user out prior to changing the security level. This issue 
is under investigation.
DDTS # CSCdz90753
In the Maintenance > Cross Connect Resource Pane, the VT matrix port detail is inconsistent with the 
general VT matrix data. This can occur when a 1+1 protection scheme is in place. To avoid confusion, 
note that the VT matrix data counts the VTs for both the working and protect card, while the detail data 
counts the VTs only for the working card. This issue is under investigation.
DDTS # CSCdz35479
Rarely, CTC Network view can freeze following the deletion or addition of a node from or to a 
BLSR/MS-SPRing. This can result in the CTC Network view no longer updating correctly. If this occurs, 
restart CTC. This issue is under investigation.
DDTS # CSCea06007
CTC does not support adding/creating more than 5 circuits in auto-ranged provisioning. This is as 
designed.
DDTS # CSCdy27484
The UCP ND-FAIL alarm is not functional. This issue will be resolved in a future release.
DDTS # CSCdy57891
An LOP-P alarm can be inadvertently cleared by an LOS that is raised and cleared. On OC48AS, OC192, 
and OC12-4 cards, when an LOP condition and an LOS condition are both present on the input, an LOS 
will be raised as per Telcordia GR 253 alarm hierarchy. However, upon clearing the LOS with the LOP 
still present, the LOP alarm, which should then be raised, is not. An AIS-P condition will be visible. This 
issue will be resolved in a future release.
DDTS # CSCdy56693
Microsoft Windows XP uses more memory than previous Microsoft operating systems, and this may 
result in reduced CTC performance. To avoid reduced performance, you can:
Limit the number of nodes you log into
Avoid or limit bulk operations
Avoid bulk circuit deletion