Release Notes for Cisco ONS 15454 Release 4.0.1
OL-4470-01
Caveats
CTC will be able to contact the topology host to learn about all the nodes in all the OSPF areas, but will 
be unable to contact any nodes that are not in the OSPF areas used by the launch node. Therefore, some 
nodes will remain disconnected in the CTC network view.
To work around this issue, if no firewall enabled, then the network configuration of the CTC host can be 
changed to allow CTC to see all nodes in the network. The launch node must be on its own subnet to 
prevent network partitioning, and craft access must not be enabled. The CTC host must be provisioned 
with an address on the same subnet as the initial node (but this address must not conflict with any other 
node in the network), and with the default gateway of the initial node. CTC will now be able to contact 
all nodes in the network.
If a firewall is enabled on any node in the network, then CTC will be unable to contact nodes outside of 
the initial OSPF areas. This issue is under investigation.
NE Defaults
The following caveats apply for NE defaults.
OC12-4 allows provisioning of PJStsMon from 0 to 48. The workaround is to limit provisioning to 
between Off and 1 to 12 only.
CTC displays “PJStsMon=off” in the standard provisioning pane when provisioning PJStsMon off; 
however, TL1 and the NE Defaults editor both display 0 for this same condition.
If you only make changes to a single default in the NE defaults editor, you must click on another 
default or column before the Apply button becomes functional.
DDTS # CSCdy35514
The terminology used for provisioning overhead circuits has changed as of Release 3.4 as follows.
Overhead Circuit Types
LDCC_TUNNEL has changed to DCC Tunnel D4-D12
SDCC_TUNNEL has changed to DCC Tunnel D1-D3
Overhead Channel Types
SDCC has changed to DCC1(D1-D3)
LDCC_TUNNEL1 has changed to DCC2(D4-D6)
LDCC_TUNNEL2 has changed to DCC3(D7-D9)
LDCC_TUNNEL3 has changed to DCC4(D10-D12)
LDCC has changed to DCC(D4-D12)
Note
These circuits are now provisioned at the network level, rather than on a node-by-node basis.
DDTS # CSCdy48478
When you generate a lamp test, the lamps on the fan tray may fail to cycle. This issue will be resolved 