Cisco Cisco ONS 15310-MA SONET Multiservice Platform Notas de publicación

Descargar
Página de 10
 
2
Release Notes for Cisco ONS 15310-MA Release 8.6.1
OL-22859-01
  Changes to the Release Notes
Changes to the Release Notes
This section documents supplemental information that has been added to the Release Notes for 
Cisco ONS 15454 Release 8.6.1
 since the production of the Cisco ONS 15454 System Software CD for 
Release 8.6.1.
Caveats
Review the notes listed below before deploying the Cisco ONS 15454. Caveats with tracking numbers 
are known system limitations that are scheduled to be addressed in a subsequent release. Caveats without 
tracking numbers are provided to point out procedural or situational considerations when deploying the 
product.
Alarms
This section documents caveats for Alarms in Release 8.6.1.
CSCtd60987—RFI-V alarm does not clear on ONS 15310 NEs in the CTM
In Software Release 8.6.1, the RFI-V alarm does not clear on ONS 15310 NEs in the Cisco Transport 
Manager (CTM). The workaround is to modify the severity of the RFI-V of the logical objects VT-MON 
and VT-TERM in the alarm profile to the same value as a customized severity. After changing the MON 
and TERM severity to the same value the RFI-V alarm is cleared in the CTM/CTC. This issue will not 
be resolved.
Common Control Cards
This section documents caveats for Common Control Cards in Release 8.6.1.
CSCtb34677 - MultiRate PPM shows PROV-MISMATCH after rate change
The PROV-MISMATCH alarm is raised on the CTX-MA card when the optical rate of a port is changed 
without changing the reach. When the rate is changed, the reach does not get configured automatically. 
The workaround is to set the reach to “auto” before changing the rate.