Changes to the Release Notes
Changes to the Release Notes
This section documents supplemental information that has been added to the Release Notes for
Cisco ONS 15454 Release 8.6.1 since the production of the Cisco ONS 15454 System Software CD for
Release 8.6.1.
Cisco ONS 15454 Release 8.6.1 since the production of the Cisco ONS 15454 System Software CD for
Release 8.6.1.
Caveats
Review the notes listed below before deploying the Cisco ONS 15454. Caveats with tracking numbers
are known system limitations that are scheduled to be addressed in a subsequent release. Caveats without
tracking numbers are provided to point out procedural or situational considerations when deploying the
product.
are known system limitations that are scheduled to be addressed in a subsequent release. Caveats without
tracking numbers are provided to point out procedural or situational considerations when deploying the
product.
Alarms
This section documents caveats for Alarms in Release 8.6.1.
CSCtd60987—RFI-V alarm does not clear on ONS 15310 NEs in the CTM
In Software Release 8.6.1, the RFI-V alarm does not clear on ONS 15310 NEs in the Cisco Transport
Manager (CTM). The workaround is to modify the severity of the RFI-V of the logical objects VT-MON
and VT-TERM in the alarm profile to the same value as a customized severity. After changing the MON
and TERM severity to the same value the RFI-V alarm is cleared in the CTM/CTC. This issue will not
be resolved.
Manager (CTM). The workaround is to modify the severity of the RFI-V of the logical objects VT-MON
and VT-TERM in the alarm profile to the same value as a customized severity. After changing the MON
and TERM severity to the same value the RFI-V alarm is cleared in the CTM/CTC. This issue will not
be resolved.
Common Control Cards
This section documents caveats for Common Control Cards in Release 8.6.1.
CSCtb34677 - MultiRate PPM shows PROV-MISMATCH after rate change
The PROV-MISMATCH alarm is raised on the CTX-MA card when the optical rate of a port is changed
without changing the reach. When the rate is changed, the reach does not get configured automatically.
The workaround is to set the reach to “auto” before changing the rate.
without changing the reach. When the rate is changed, the reach does not get configured automatically.
The workaround is to set the reach to “auto” before changing the rate.