Cisco Cisco ONS 15310-CL SONET Multiservice Platform Guía De Instalación

Descargar
Página de 8
 
5
Installing the ML100T-8 Card in the Cisco ONS 15310-CL and Cisco ONS 15310-MA
78-17412-01
  Install the ML100T-8 Card in the Cisco ONS 15310-CL
Install the ML100T-8 Card in the Cisco ONS 15310-CL 
Use this section if you are installing the ML100T-8 card in an ONS 15310-CL expansion slot for the first 
time. After you become familiar with ONS 15310-CL card installation and bootup, use this section as a 
reference.
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to 
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) 
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not 
operate the system unless all cards, faceplates, front covers, and rear covers are in place. 
Statement 1029
Caution
Do not install the ML100T-8 card in an ONS 15310-CL if the ambient temperature exceeds 131 degrees 
Fahrenheit (55 degrees Celsius).
Step 1
Install the ML100T-8 card in the expansion slot (
a.
Open the card ejector.
b.
Slide the card along the guide rails into the slot.
c.
Close the ejector by pushing it to the right.
d.
Lock the cards into place by tightening the ejector locking screws.
Note
The ML100T-8 cards are hot-pluggable, so they may be inserted or removed without turning off 
the power to the ONS 15310-CL.