Installing the ML100T-8 Card in the Cisco ONS 15310-CL and Cisco ONS 15310-MA
78-17412-01
  Install the ML100T-8 Card in the Cisco ONS 15310-MA
Figure 2
Installing the Cisco ONS 15310-CL ML100T-8 Card 
Step 2
Verify the ML100T-8 card LED activity:
a.
Verify that the red FAIL LED is off
b.
Verify that the green ACT LED is on.
Step 3
If you remove power from the ONS 15310-CL chassis, and then restore it, check the chassis LED 
activity:
a.
Verify that the chassis red FAIL LED blinks for 20 to 30 seconds, then turns off.
b.
Verify that the chassis ALARM LED is off.
c.
Verify the chassis green PWR LED is on. (It is amber only if one DC power source is on and 
operating.)
d.
Verify that the chassis green SYNC LED is on.
Step 4
When you log into CTC, verify that the card appears properly on the CTC node view screen.
Stop. You have completed this procedure.
Install the ML100T-8 Card in the Cisco ONS 15310-MA
Use this section if you are installing the ML100T-8 card in an ONS 15310-MA expansion slot for the 
first time. After you become familiar with ONS 15310-MA card installation and bootup, use this section 
as a reference.
124657