Cisco Cisco ONS 15454 SDH Multiservice Provisioning Platform (MSPP) Guía De Instalación
4
Installing ONS 15454 SDH E3-12 Cards
78-14606-01
E3-12 Card
E3-12 Specifications
•
E3-12 Input
–
Bit Rate: 34.368 MBits/s (Mbps) + 20 ppm
–
Line Code: HDB-3
–
Termination: Unbalanced coaxial cable
–
Input Impedance: 75 ohms + 5%
–
Cable Loss: up to 12 dB @ 17184 kHz (for cable length see specification of the cable that you
are using)
are using)
–
AIS: ITU-T G.704-compliant
•
E3-12 Output
–
Bit Rate: 34.368 MBits/s (Mbps) + 20 ppm
–
Line Code: HDB-3
–
Termination: Unbalanced coaxial cable
–
Output Impedance: 75 ohms + 5%
–
AIS: ITU-T G.704-compliant
–
Power Level: -1.8 - +5.7 dBm
–
Pulse Shape: ITU-T G.703, Figure 17
–
Pulse Amplitude: 0.36 - 0.85 V peak-to-peak
–
Loopback Modes: Terminal and Facility
•
E3-12 Electrical Interface
–
Connectors: 1.0/2.3 Miniature Coax connectors in FMEC-E3/DS3
•
Environmental
–
Overvoltage Protection: as in ITU-T G.703 Annex B
–
Operating Temperature: -5 to +45 degrees Celsius
–
Operating Humidity: 5 - 95%, non-condensing
–
Power Consumption: 38.20 W, 0.80 A (AMPS) @ -48V, 130.4 BTU/Hr.
•
Dimensions
–
Height: 321.3 mm, (12.650 in.)
–
Width: 18.2 mm, (0.716 in.)
–
Depth: 228.6 mm, (9.000 in.)
–
Depth with backplane connector: 235 mm, (9.250 in.)
–
Weight not including clam shell: 0.7 kg (1.7 lbs.)
•
Compliance
ONS15454 SDH cards, when installed in a system, comply with these standards:
ONS15454 SDH cards, when installed in a system, comply with these standards:
–
Safety: IEC 60950, EN 60950, UL 60950, CSA C22.2 No. 60950, TS 001, AS/NZS 3260