Cisco Cisco ONS 15454 SDH Multiservice Provisioning Platform (MSPP) Guía De Instalación
![Cisco](https://files.manualsbrain.com/attachments/7380d0050044647c30f5c24bbbf5d0c0b6d9bb84/common/fit/150/50/faa183d287233c52228cfea3dbc2a127fe780f60564fcb0955d9c3d1cd23/brand_logo.png)
6
Installing ONS 15454 SDH E3-12 Cards
78-14606-01
Removal Procedures
Card Turn Up
Follow the steps in this section to verify card turn up. If one or more of the Cisco Transport Controller
(CTC) software screen conditions according to
(CTC) software screen conditions according to
are not met, re-install the card. Replace the unit if the faulty state persists.
Verify Successful Turn Up of the E3-12 Card
Step 1
Verify that power is applied to the shelf assembly.
Step 2
Verify that the E3-12 card has been installed in the correct slot.
Step 3
Verify that the card appears in the correct slot on the CTC software screen.
Step 4
Verify that the card is white on the CTC software screen.
Step 5
Verify that the card is shown in Inventory on the CTC software screen.
Removal Procedures
Use this section if you are installing or removing the E3-12 card for the first time. After you become
familiar with ONS 15454 SDH card installation and boot up, use this section as a reference.
familiar with ONS 15454 SDH card installation and boot up, use this section as a reference.
Caution
Always use the supplied electrostatic discharge (ESD) wristband when working with an ONS 15454
SDH. Plug the wristband cable into the ESD jack located on the lower right outside edge of the shelf
assembly and ensure the shelf assembly is properly grounded.
SDH. Plug the wristband cable into the ESD jack located on the lower right outside edge of the shelf
assembly and ensure the shelf assembly is properly grounded.
Caution
Hazardous voltage or energy may be present on the backplane when the system is operating. Use caution
when servicing.
when servicing.
Note
Traffic can be interrupted if you pull an active card from the ONS 15454 SDH. Use caution when
replacing cards and verify that only inactive or standby cards are being replaced. If an active card needs
to be replaced, follow the procedure to switch the electrical card to standby mode before you pull the
card from the node.
replacing cards and verify that only inactive or standby cards are being replaced. If an active card needs
to be replaced, follow the procedure to switch the electrical card to standby mode before you pull the
card from the node.
Reset an Electrical Card (E1-N-14, DS3iN-12, or E3-12)
Note
An electrical card reset can cause a linear 1:1 or 1:N protection switch or an MSSPRing protection
switch.
switch.
The cards should be replaced when the red FAIL LED appears.