Low or Degraded Reverse RF Signal 
Low or Degraded Reverse RF Signal 
The reverse RF signal can be measured at the amplifier module Main, Aux 1, and Aux 
2 reverse input and reverse output test points. 
 
Low or Degraded Reverse RF Signal Troubleshooting Table 
Before you begin troubleshooting for a low or degraded reverse RF signal, verify that 
the amplifier is receiving the proper reverse RF input signals from the downstream 
amplifiers at the amplifier module Main, Aux 1, and Aux 2 reverse input test points. 
Important: You cannot balance the amplifier without the proper reverse RF input 
signals. 
Make sure you have configured the amplifier module according to the specifications 
in the design print, and that the amplifier has warmed up for approximately one 
hour. 
Make sure you are using the proper total tilt reference when setting receive levels. 
Refer to the reverse equalizer charts in Technical Information (on page 93) for more 
information. 
Important: If the amplifier cover was ever removed, make sure it was properly 
reinstalled. Improperly reinstalling the amplifier module cover may result in RF 
signal degradation. 
Possible cause 
Solution 
Low or degraded reverse RF signal at 
the reverse input test point(s). 
 
Verify that the amplifier is receiving the proper 
reverse RF input signals from the downstream 
amplifiers. 
Important: You cannot balance the amplifier 
without the proper reverse RF input signals. 
 