Cisco Cisco 1 GHz GainMaker Amplifier Guía De Instalación

Descargar
Página de 132
Chapter 4    Troubleshooting 
 
 
 
Possible cause 
Solution 
There are proper reverse RF signals 
at the Main, Aux 1, and Aux 2 
reverse input test points, but a low or 
degraded signal at the reverse output 
test point. 
 
Verify that the amplifier module is receiving 
the proper DC voltages. Refer to No DC Power 
(on page 83). 
 
Measure the main reverse input test point and 
the reverse output test point. Subtract the 
reverse amplifier gain and add the pad values 
and EQ insertion loss to verify proper reverse 
amplifier gain. 
 
Verify that all the proper accessories, pads, 
EQs, and signal directors (if applicable) are 
firmly installed in the correct locations. 
 
Verify that the factory installed accessories are 
firmly installed in the correct locations. 
 
Verify that the reverse switch and its jumpers 
are properly and firmly installed. 
Note: Verifying factory installations involves 
removing the amplifier module cover. Reinstall 
the amplifier module cover properly or RF 
signal degradation may result. 
Reverse RF signal still low or 
degraded. 
 
Verify that any unused RF ports are properly 
terminated. 
 
Use a spectrum analyzer to look at the reverse 
RF input signal spectral quality at each reverse 
input test point and compare it to the reverse 
RF output signal spectral quality. 
– 
If degradation is generated in the reverse 
amplifier, replace the reverse amplifier. 
– 
If degradation is generated by the 
downstream amplifier reverse RF signal, 
troubleshoot the RF amplifier feeding this 
station. 
 
Replace the amplifier module. 
 
 
 
90 
OL-31156-01