Chapter 2    Installation and Configuration 
 
 
 
Closing the Node Housing 
To Close the Node Housing 
Complete the following steps to close the node housing. 
 
CAUTION: 
Avoid moisture damage and RF leakage! Follow the procedure exactly as 
shown below to ensure a proper seal. 
1  Make sure that the housing gaskets are clean and in the correct position. Wipe off 
any excess dirt and debris. 
2  Close the housing. 
 
CAUTION: 
Ensure that all the cables are out of the way when closing the housing. 
3  Lightly secure the six ½-inch closure bolts with a hex driver or ratchet. 
4  Using a torque wrench, tighten the six closure bolts to 25 in-lb (2.8 Nm). 
Important: Tighten the closure bolts in the correct sequence as specified in 
Torquing Sequence (on page 44). 
5  Using the same pattern, tighten the housing closure bolts from 5 ft-lb to 12 ft-lb 
(6.8 Nm to 16.3 Nm). 
 
Torquing Sequence 
The following diagram shows the proper torquing sequence for the housing closure 
bolts. 
 
 
 
44 