Chapter 3    Balancing and Setup 
 
 
 
1  Balance all of the reverse amplifiers off a given reverse input port for the node 
being worked on. The reverse amplifiers should be balanced sequentially from 
the node outward. 
Note: Make sure the reverse fiber link has been properly balanced before 
proceeding. 
2  Ensure that the design value reverse output equalizer and reverse pads are 
installed in the appropriate reverse slots in the amplifier. Refer to the following 
diagram. 
Note: Record the pad values for each input port for later use. 
 
3  Proceed to 
To Calculate the Proper RF Signal Level (on page 74). 
 
 
To Calculate the Proper RF Signal Level 
In order to calculate the correct RF signal level to inject, you must know the 
following. 
 
Design Reverse Port Input Level from the design print 
 
Total Injection Insertion Loss (20 dB) 
To calculate the correct signal level to inject, add the total injection insertion loss to 
the design port input level. 
Example 
 
Design amplifier reverse port input level = 19 dBmV 
 
Total injection insertion loss = 20 dB 
The design amplifier reverse port input level plus injection insertion loss equals 
correct RF signal level to inject. 
In the example shown above, 19 dBmV + 20 dB = 39 dBmV. Therefore, you would set 
the signal generator output for + 39 dBmV. 
Important:  
 
74 