Cisco Cisco UCS B200 M2 Blade Server Libro blanco
The Properties for: FC Interface x/x window will appear. In the Fill Pattern section, confirm that the Arbff radio button is
chosen.
chosen.
Click OK.
Repeat for all FC ports connected between the fabric interconnects and the Brocade switches.
Enable Cisco UCS to Brocade Fibre Channel Uplinks
Brocade
All licensed Brocade ports are enabled by default. For this example the port has been explicitly disabled to demonstrate the
enabling of the port.
All licensed Brocade ports are enabled by default. For this example the port has been explicitly disabled to demonstrate the
enabling of the port.
The state of a Brocade port can be viewed with the
portshow command:
Brocade-A:admin> portshow 0
portIndex: 0
portName: port0
portHealth: No Fabric Watch License
Authentication: None
portDisableReason: None
portCFlags: 0x0
portFlags: 0x21 PRESENT U_PORT DISABLED
LocalSwcFlags: 0x0
portType: 18.0
POD Port: Port is licensed
portState: 2 Offline
.
.