Chapter 3 Installation
22
78-4039426-01 Rev D
Connecting the Component Video Output
Connect a video monitor to the connectors labeled Pr, Pb, and Y.
Connecting the Composite Video Output
Connect a video monitor to the CVSB 1 and CVSB 2 connectors. The two outputs are
identical. Use a 75-ohm double-braided coax cable.
identical. Use a 75-ohm double-braided coax cable.
Connecting the Balanced Audio Outputs
1 Connect the AUDIO 1 and AUDIO 2 balanced audio outputs to monitoring
equipment. Use a multi-conductor, pluggable cable from the receiver's AUDIO 1
and AUDIO 2 (Left and Right) terminals to your equipment, as shown in the
following illustration.
and AUDIO 2 (Left and Right) terminals to your equipment, as shown in the
following illustration.
Connector
Connector type
Terminal Block
2 Feed the stripped ends of the positive, negative and ground wires into the
appropriate terminals as labeled, and then screw the terminal screws (located on
the top of the terminal block) finger tight to each wire.
the top of the terminal block) finger tight to each wire.
Connecting the Ethernet Management Interface
The RJ-45 interface for 100/1000 BaseT Ethernet is currently intended for
upgrading/downloading the software application. You must set up the IP address,
the default gateway and the subnet mask to match the network connection. This is
done through the front panel menu. For further information, see Setting up for
Network Connection (on page 3).
upgrading/downloading the software application. You must set up the IP address,
the default gateway and the subnet mask to match the network connection. This is
done through the front panel menu. For further information, see Setting up for
Network Connection (on page 3).
Note: Proper cables are required for reliable Ethernet operation; to run up to a
maximum segment length of 100 m and up to 100baseT, the cable has to comply with
the EIA/TIA Category 5 (or higher) wire specifications, and for 1000baseT, Category
6 is required. For EMC protection, shielded cables must be used.
1 Connect an RJ-45 cable between the Ethernet connector on the D9824 receiver
maximum segment length of 100 m and up to 100baseT, the cable has to comply with
the EIA/TIA Category 5 (or higher) wire specifications, and for 1000baseT, Category
6 is required. For EMC protection, shielded cables must be used.
1 Connect an RJ-45 cable between the Ethernet connector on the D9824 receiver
and the Ethernet port of your PC.
2 Set up the IP address on the D9824 receiver (via the front panel display). For
information on setting up the IP address via the front panel, see Setting up for
Network Connection (on page 3).
Network Connection (on page 3).