Cisco Cisco Web Security Appliance S190 Guía Del Usuario
20-29
AsyncOS 8.1 for Cisco Web Security User Guide
Chapter 20 Monitor System Activity Through Logs
Access Log Customization
Access Log Customization
•
•
•
Related Topics
•
.
Customizing Standard Access Logs
Step 1
Choose System Administration > Log Subscriptions.
Step 2
Click the access log file name to edit the access log subscription.
Step 3
Enter the required format specifiers in the Custom Field.
The syntax for entering format specifiers in the Custom Field is as follows:
<format_specifier_1> <format_specifier_2> ...
For example:
%a %b %E
You can add tokens before the format specifiers to display descriptive text in the access log file. For
example:
example:
client_IP %a body_bytes %b error_type %E
where
client_IP
is the description token for log format specifier
%a
, and so on.
Note
You can create a custom field for any header in a client request or a server response.
Step 4
Submit and commit your changes.
Related Topics
•
.
•
.
•
.
Customizing W3C Access Logs
Step 1
Choose System Administration > Log Subscriptions
Step 2
Click the W3C log file name to edit the W3C log subscription.
Step 3
Type a field in the Custom Field box, and click Add.
The order the fields appear in the Selected Log Fields list determines the order of fields in the W3C
access log file. You can change the order of fields using the Move Up and Move Down buttons. You can
remove a field by selecting it in the Selected Log Fields list and clicking Remove.
access log file. You can change the order of fields using the Move Up and Move Down buttons. You can
remove a field by selecting it in the Selected Log Fields list and clicking Remove.