Cisco SM-X-1T3/E3 Enhanced Service Module Configuration Guide
OL-27148-02
Cisco SM-X-1T3/E3 Enhanced Service Module Configuration Guide
  Configuring the SM-1T3/E3 Service Module
Enabling the Backplane
The SM-X-1T3/E3 communicates with the host router through an internal Gigabit Ethernet (GE) 
interface. This GE interface connects to the multi-gigabit fabric (MGF). For the SM to function, the GE 
interface must be enabled.
Perform this task to enable the GE interface on 2900 and 3900 Series ISRs: 
1.
enable
2.
configure terminal
3.
interface sm slot/port
Note
The backplane is always port 1. /port should always be set to 1.
4.
no shut
5.
exit
DETAILED STEPS
Step 5
no shut
Example:
Router(config-if)# no shut
Enables the interface IP address.
Step 6
exit
Example:
Router(config-if)# exit
Exits interface configuration mode and returns to privileged 
EXEC mode.
Command or Action
Purpose
Command or Action
Purpose
Step 1
enable
Example:
Router> enable
Enables privileged EXEC mode. 
Enter the password if prompted.
Step 2
configure
 terminal
Example:
Router# configure terminal
Enters global configuration mode.