Cisco SM-X-1T3/E3 Enhanced Service Module Configuration Guide
OL-27148-02
Cisco SM-X-1T3/E3 Enhanced Service Module Configuration Guide
  Configuring the SM-1T3/E3 Service Module
SUMMARY STEPS
1.
enable
2.
configure terminal
3.
card type t3 slot
4.
controller t3 slot/port
5.
framing {c-bit m23 }
6.
cablelength feet
7.
clock source internal line }
8.
exit
DETAILED STEPS
Command or Action
Purpose
Step 1
enable
Example:
Router> enable
Enables privileged EXEC mode. 
Enter the password if prompted.
Step 2
configure
 terminal
Example:
Router# configure terminal
Enters global configuration mode.
Step 3
card type t3
 slot
Example:
Router (config)# card type t3 1
Selects the card type.
Creates a T3 controller and a serial interface.
t3—Selects the T3 controller.
slot—Slot number of the interface.
By default, the T3 controller does not appear in the 
show running-config output.
Step 4
controller t3
 slot/port
Example:
Router(config)# controller t3 1/0
Specifies the T3 controller and enters controller 
configuration mode.
slot/port—Backplane slot number and port number on 
the controller.
Step 5
framing
 {c-bit m23}
Example:
Router(config-controller)# framing c-bit
Specifies the framing type.
c-bit—Specifies C-bit framing as the T3 framing type.
m23—Specifies M23 framing as the T3 framing type.
Step 6
cablelength 
feet
Example:
Router(config-controller)# cablelength 250
Specifies the distance from the routers to the network 
equipment.
feet—Number of feet in the range from 0 to 450.
The default value is 224 feet.