Cisco Cisco UCS C3260 Rack Server Hoja De Datos
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
84
TECHNICAL SPECIFICATIONS
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
Environmental Specifications
The power specifications for the C220 M3 server are listed in
Input connector
3 wire Connector (Molex MINIFIT SR. R/A )
Table 46 UCS C220 M3 Environmental Specifications
Parameter
Minimum
Temperature operating
41 to 104° F (5 to 40° C)
derate the maximum temperature by 1°C per every 305m of
derate the maximum temperature by 1°C per every 305m of
altitude above sea level
Temperature nonoperating
–40 to 149°F (–40 to 65°C)
Humidity (RH) nonoperating,
non-condensing
10 to 90%
Altitude operating
0 to 3,000 m (0 to 10,000 ft.)
Altitude nonoperating
0 to 12,192 m (0 to 40,000 ft.)
Sound Power level, Measure
A-weighted per ISO7779 LWAd (Bels)
Operation at 73°F (23°C)
5.4
Sound Pressure level, Measure
A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
37
Table 45 UCS C240 M3 SFF Power Specifications (930 W DC V2 power supply) (continued)
Description
Specification