Cisco Cisco IOS Software Release 12.4(23) Notas de publicación

Descargar
Página de 610
523
Caveats for Cisco IOS Release 12.4
OL-7656-15 Rev. J0
  Resolved Caveats—Cisco IOS Release 12.4(8)
Conditions: This symptom is observed on a Cisco platform that runs Cisco IOS Release 12.4 or 
Release 12.4T when you enter the ip route-cache flow or ip flow ingress command on an interface.
Workaround: Do not configure NetFlow on an interface. 
CSCsd65404
Symptoms: Control packets are not properly marked with the ToS setting that is specified in an 
IP SLA probe. Only the data packets are marked with the configured ToS setting.
Conditions: This symptom is observed when an IP SLA probe is configured via SNMP. Note that 
the symptom does not occur when the IP SLA probe is configured via the CLI.
Workaround: Configure the IP SLA probe via the CLI. However, this workaround does not scale 
well for networks in which a large number of probes must be configured. 
EXEC and Configuration Parser
CSCsd32923
Symptoms: A router may unexpectedly reload with a bus error when you enter a command while the 
command buffer is full of white space.
Conditions: This symptom is observed when you enter a partial command and when the tab key is 
used while the command buffer is full.
Workaround: There is no workaround. 
Interfaces and Bridging
CSCdp08975
Symptoms: Even though traffic is flowing through ATM VCs, the status of the ATM VCs may 
change unexpectedly.
Conditions: This symptom is observed on a Cisco 7200 series that has RFC1577 configured on the 
main interface and that does not function as an Address Resolution Protocol (ARP) server.
Workaround: Do not configure RFC1577 on the main interface. Rather, configure RFC1577 on a 
subinterface. 
CSCek27126
Symptoms: A router may crash when you remove a label-controlled ATM (LC-ATM) subinterface 
and may generate an “%ALIGN-1-FATAL: Corrupted program counter” error message.
Conditions: This symptom is observed on a Cisco 7200 series but may be platform-independent.
Workaround: Shut down the main interface before you remove the subinterface. 
CSCsc66187
Symptoms: Error messages such as the following one may be generated on a Cisco 7500 series or 
Cisco 7600 series:
%CWPA-3-IPCALLOCFAIL: Failed to allocate IPC buffer for loveletter data
Conditions: This symptom is observed on a Cisco 7500 series and Cisco 7600 series that are 
configured with a 1-port Packet-over-SONNET OC-3c/STM-1 multimode port adapter 
(PA-POS-OC3MM) when you enter the no shutdown interface configuration command on the 
interface.