Cisco Mesh Access Points, Design and Deployment Guide, Release 7.0
OL-21848-01
  Mesh Network Components
electrical wiring. On the outside of the housing is a hazardous location certification label (CSA, ATEX, 
or IEC) that identifies the type of certifications and environments that the equipment is approved for 
operation.
Note
Power entry module for CSA (USA & CANADA) is Power Entry Module, Groups A,B,C,D with 
T5v(120º C) temp code.
Power Entry Module for ATEX (EU) is Power entry module Groups IIC, IIB, IIA with T5 (120º C) temp 
code.
Hazardous Certification (Div 1 > Div 2 and Zone 1 > Zone 2)
Class 1, Division 1/Zone 1 is for environments with full-time ignitable concentrations of flammable 
gases, vapors, or liquids. To meet the requirements of the Div 1 > Div 2 and Zone 1 > Zone 2 locations, 
we recommend a TerraWave Solutions CSA certified protective Wi-Fi enclosure (see 
).
For more information about the TerraWave enclosures, see 
Cisco Wireless LAN Controllers
The wireless mesh solution is supported by Cisco 2100 Series, Cisco 4400 Series Wireless LAN 
Controllers, and 5500 Series Wireless LAN Controllers. The Cisco 5500 and 4400 Series Controllers 
(see 
) are recommended for wireless mesh deployments because they can scale to large 
numbers of access points and can support Layer 3 CAPWAP.
Figure 14
Cisco 5500 Wireless LAN Controller
For more information about the Cisco 5500, 4400, and 2100 Wireless LAN Controllers, see: 
Table 8
TerraWave Enclosures
Access Point Model
Enclosure Part No
Description
1240
TerraWave  XEP1242
18 x12 x8 Protective Wi-Fi Enclosure that 
includes the Cisco 1242 Access Point
1522, 1524
TerraWave Part 
Number: XEP1522
18 x 12 x8 Protective Wi-Fi Enclosure 
that includes the Cisco 1522 Access Point