Cisco Cisco Aironet 1522 Lightweight Outdoor Mesh Access Point Guía De Diseño

Descargar
Página de 216
60
Cisco Mesh Access Points, Design and Deployment Guide, Release 7.0
OL-21848-01
  Connecting the Cisco 1520 Series Mesh Access Point to Your Network
Software Upgrade Procedure
When you upgrade the controller’s software, the software on the controller’s associated mesh access 
points is also automatically upgraded. When a mesh access point is loading software, each of its LED 
blinks in succession.
Caution
Do not power down the controller or any mesh access point during this process; otherwise, the software 
image may become corrupted. Upgrading a controller with a large number of mesh access points can 
take around 30 minutes, depending on the size of your network. The mesh access points must remain 
powered on, and the controller must not be reset during this time.
Caution
Controller software release 7.0 is greater than 32 MB; therefore, you must verify that your TFTP server 
supports files of this size. Two TFTP servers that support files of this size are tftpd and the TFTP server 
within Cisco WCS. If you download the software and your TFTP server does not support files of size 
greater than 32 MB, then a TFTP failure while storing in flash error message appears. 
Caution
Upgrade to release 5.2 from the latest 4.1.192.xxM mesh release prior to upgrading to release 7.0. 
Upgrading directly to release 5.2 from either 4.1.190.05 or 4.1.191.22M is not supported. For details on 
upgrading to the latest version of 4.1.192.xxM from an earlier mesh release, see the 
“Upgrade 
Compatibility Matrix” 
section in the
 
Release Notes for Cisco Wireless LAN Controllers and Mesh Access 
Points for Release 4.1.192.35M (or later) at 
http://www.cisco.com/en/US/products/ps6366/prod_release_notes_list.html
Note
When upgrading to an intermediate software release as part of the 4.1.192.xxM to release 5.2 and then 
to release 7.0 controller software upgrade, ensure that all mesh access points associated with the 
controller are at the same intermediate release before preceding to install the next intermediate or final 
version of software. In large networks, it can take some time to download the software on each mesh 
access point.
Note
If you are upgrading from mesh release 4.1.191.22M to the latest 4.1.192.xxM before upgrading to the 
release 5.2 (prior to upgrading to release 6.0), you must manually reset the controller immediately after 
the upgrade without saving the configuration. Ensure to check the RRM configurations after the upgrade 
to see if all match your earlier configurations.
Caution
A backup of your controller configuration file is recommended prior to any software upgrade. Without 
this backup, you will need to manually reconfigure the controller should the configuration file be lost or 
corrupted or if you need to downgrade.