  Cabling the Device
Firepower 7000 Series Getting Started Guide
8
Inline Interface Cabling 
For each network segment you want to monitor inline, connect the appropriate cables (either copper or fiber 
sequentially to pairs of sensing interfaces.
Use this cabling when you want to configure inline, inline with fail-open, switched, routed, or hybrid interfaces.
Firepower 7010/7020/7030/7050
Inline with Fail-Open Configuration
If you want to take advantage of the device’s configurable fail-open capability, you must cable a sequential pair 
of vertical interfaces (interfaces 1 and 2, 3 and 4, 5 and 6, or 7 and 8) to a network segment.
After you cable the interfaces, use the web interface on the Defense Center that manages the device to configure 
the interface as inline with fail-open. See Setting Up an IPS Device in the Firepower Management Center 
Configuration Guide
.
Firepower 7110/7120
Inline with Fail-Open Configuration
If you want to take advantage of the device’s configurable fail-open capability, you must cable a sequential pair 
of interfaces (interfaces 1 and 2, 3 and 4, 5 and 6, or 7 and 8) to a network segment.
After you cable the interfaces, use the web interface on the Defense Center that manages the device to configure 
the interface as inline with fail-open. See Setting Up an IPS Device in the Firepower Management Center 
Configuration Guide
.