Cisco Cisco Email Security Appliance C170 Guía Del Usuario
32-42
Cisco AsyncOS 8.5 for Email User Guide
Chapter 32 Managing and Monitoring Using the CLI
SNMP Monitoring
All models can use SNMP to monitor disk drive health and the link status of Network Interfaces.
Hardware Traps
lists the temperature and hardware conditions that cause a hardware trap to be sent:
Status change traps are sent when the status changes. Fan Failure and high temperature traps are sent
every 5 seconds. The other traps are failure condition alarm traps — they are sent once when the state
changes (healthy to failure). It is a good idea to poll for the hardware status tables and identify possible
hardware failures before they become critical. Temperatures within 10 per cent of the critical value may
be a cause for concern.
every 5 seconds. The other traps are failure condition alarm traps — they are sent once when the state
changes (healthy to failure). It is a good idea to poll for the hardware status tables and identify possible
hardware failures before they become critical. Temperatures within 10 per cent of the critical value may
be a cause for concern.
Note that failure condition alarm traps represent a critical failure of the individual component, but may
not cause a total system failure. For example, a single fan or power supply can fail on a C600 appliance
and the appliance will continue to operate.
not cause a total system failure. For example, a single fan or power supply can fail on a C600 appliance
and the appliance will continue to operate.
C300/C600
/X1000
/X1000
2
1
1
1
6
2
4 (C300
has 2)
has 2)
3 (5 for
C600 and
X1000 with
fiber
interface)
C600 and
X1000 with
fiber
interface)
C350/C650
/X1050
/X1050
2
1
0
0
4
2
4 (C350
has 2)
has 2)
3 (5 for the
C650 and
x1050 with
fiber
interface)
C650 and
x1050 with
fiber
interface)
Table 32-11
Number of Hardware Objects per Cisco Appliance
Model
CPU
Temp
Temp
Ambient
Temp
Temp
Backplane
Temp
Temp
Riser
Temp
Temp
Fans
Power
Supply
Status
Supply
Status
Disk
Status
Status
NIC Link
Table 32-12
Hardware Traps: Temperature and Hardware Conditions
Model
High
Temp
(CPU)
Temp
(CPU)
High Temp
(Ambient)
(Ambient)
High Temp
(Backplane)
(Backplane)
High
Temp
(Riser)
Temp
(Riser)
Fan
Failure
Failure
Power
Supply
Supply
RAID
Link
C10/C10
0
0
90C 47C NA
NA 0
RPMs
Status
Change
Change
Status
Change
Change
Status
Change
Change
C30/C60
NA
NA
NA
NA
NA
NA
Status
Change
Change
Status
Change
Change
C300/C6
00/X1000
00/X1000
90C 47C 72C
62C 0
RPMs
Status
Change
Change
Status
Change
Change
Status
Change
Change
C350/C6
50/X1050
50/X1050
90C
47C
NA
NA
0 RPMs Status
Change
Status
Change
Change
Status
Change
Change