policy. It is highly recommended to set a 
password on the unit during install using the 
API command: ‘systemtools passwd’. 
CSCtr32331 
C20 
A C20 participating in a MultiSite will not be 
able to send the following video formats in its 
main video channel: 1280*768, 1280*800 and 
1440*900. 
N/A 
TC4.x and later 
If the ‘admin’ user is deleted, the TMS will not 
be able to manage the system. At the same 
time the ‘admin’ user with a blank password will 
be recreated during next reboot if no other user 
with admin access exists. 
N/A 
TC4.x and later 
xFeedback register Event/KeyDown masks the 
keys pressed on the remote control with a ‘*’. 
This is a security measurement to prevent key 
logging from the remote control. The ‘*’ can be 
used to detect if someone has pressed a button 
on the remote control. 
 
TC4.x 
If you downgrade from TC4.x.x to any software 
less than TC4.0.0 and have set the IP stack to 
IPv6, the system will be unusable. The stack 
will still think it should do IPv6 even though 
there is no place to configure this in pre 
TC4.0.0 code. The workaround will be to factory 
reset the system. Even if the system does not 
report any IP address, it will still have an IPv4 
address. If you can’t get hold of this address, 
you will have use RS-232 to restore the unit or 
the procedure of using the power button (for 
C20, EX60 and EX90). 
N/A 
TC4.1.0 
The Cisco TelePresence Touch 8 screen does 
not support up loadable layout families. Hence 
you should not use the Cisco TC Console to 
upload layouts to a system with the Cisco 
Touch 8 screen attached. 
N/A 
Cisco TelePresence Touch 
TC4.1.0/TT2.1.0 
The Cisco TelePresence Touch 8 must be 
connected to the same subnet as the codec it is 
pairing to. 
N/A 
TMS 12.6 or below when upgrading to 
TC4.0.0 and above 
Starting with TC4.0, the security model used by 
the system changes which impacts compatibility 
with existing installations of TMS. The 
incompatibilities will result in: 
  
1) Upgrading endpoints from a version less 
than TC4.0 to a version TC4.0 or higher using 
existing versions of TMS (12.x or lower) will 
appear to have failed in TMS.  Additionally, the 
endpoint will not get the required release key 
updated, so the endpoint will not be able to 
make calls until a release key has been entered 
into the system.  
2) After an endpoint is upgraded to TC4.0 or 
newer, the system will have an incorrect 
username or password error message in TMS 
and TMS will not be able to communicate with it 
properly. 
 
 
A workaround to restore communication 
with TMS will be: 