Cisco Cisco Aironet 1530i Outdoor Access Point Guía De Instalación

Descargar
Página de 6
3
Cisco Aironet 1530 Series Outdoor Access Point Power Adapter AIR-PWRADPT-1530 Series
OL-31502-01
  Technical Specifications
Technical Specifications
All parameters listed in the following table are specified at 230VAC input, rated load, 25°C 70% RH 
ambient.
Output
DC Voltage
1
48V
Rated Current
1.25A
Current Range
0 ~ 1.25A
Rated Power (Max.)
60W
Ripple and Noise 
(Max)
2
240mVp-p
380mVp-p for Japan version only
Voltage Tolerance
3
±3.5%
Line Regulation
4
±1.0%
Load Regulation
±2.5%
Setup, Rise Time
5
600ms, 30ms / 230VAC
600ms, 30ms / 115VAC at full load
Hold Up Time (Typ.)
50ms / 230VAC
15ms / 115VAC at full load
Input
Voltage Range
6
100 ~ 264VAC 
90 ~ 264VAC for Japan version only
Frequency Range
47 ~ 63Hz
Efficiency (Typ.)
92%
AC Current
1.4A / 115VAC
1A / 230VAC
Inrush Current (Max.)
65A / 230VAC
Leakage Current (Max.) 0.75mA / 240VAC
Protection
Overload
105 ~ 150% rated output power
Protection type—Hiccup mode, recovers automatically after fault 
condition is removed
Over Voltage
50.4 ~ 64.8V
Protection type—Shut down o/p voltage, re-power on to recover
Over Temperature
RTH2 > 70°C
Protection type—Shut down o/p voltage, re-power on to recover
Environment
Working Temp.
-30 ~ + 60°C (Refer to output load derating curve)
Working Humidity
0% - 100% RH condensing
Intrusion Protection
IP67
Storage Temp.
-30 ~ +85°C
Temp. Coefficient
± 0.03% / °C (0 ~ 50°C)
Vibration
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UV Rating (cable)