Cisco Cisco Aironet 1530i Outdoor Access Point Guía De Instalación

Descargar
Página de 6
4
Cisco Aironet 1530 Series Outdoor Access Point Power Adapter AIR-PWRADPT-1530 Series
OL-31502-01
  Mechanical Specifications
Mechanical Specifications
All measurements in the following figure are in mm.
1000²50
SVT 18AWGØ2C
ȶ4.2Ø4PL
1000²50
25 
(MAX)
9.6
11.9
147.2
171
61.5
46.5
32
36.
8
1
2
Pin No.
1
2
Assignment
.W
,W
352474
Safety and EMC
Safety Standards
UL/cUL60950-1, TUV EN60950-1, CCC GB4943, S-mark (Argentina), 
EAC (Russia), NOM (Mexico), SAA (Australia), KC (Korea), BMSI 
(Taiwan)
PSE (Japan) for AIR-PWRADPT2-1530= only
Withstand Voltage
I/P-O/P:3KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC
Isolation Resistance
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMI Conduction and 
Radiation
EN55022 class B, FCC PART 15 / CISPR22 class B, CNS13438 class B, 
GB9254 class B
Harmonic Current
Compliance to EN61000-3-2,3, GB17625.1
EMS Immunity
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
1.
DC voltage: The output voltage set at point measure by plug terminal & 50% load.
2.
Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.
Tolerance: includes set up tolerance, line regulation, load regulation.
4.
Line regulation is measured from low line to high line at rated load.
5.
Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
6.
Maximum input voltage is 305VAC without IEC connector