Cisco Cisco Packet Data Interworking Function (PDIF)
Global Configuration Mode Commands (T-threshold phspc)
▀ threshold dcca-protocol-error
▄ Command Line Interface Reference, StarOS Release 16
5504
threshold dcca-protocol-error
Configures alarm or alert thresholds for Diameter Credit Control Application (DCCA) protocol errors from the
Diameter server.
Diameter server.
Product
ACS
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration
configure
Entering the above command sequence results in the following prompt:
[local]host_name(config)#
Syntax
threshold dcca-protocol-error high_thresh [ clear low_thresh ]
default threshold dcca-protocol-error
default
Disables the threshold for configured alarm and sets the
high_thresh
and
low_thresh
values to 0.
high_thresh
Default: 0
Specifies the high threshold number of protocol error received from Diameter server that must be met or
exceeded within the polling interval to generate an alert or alarm.
Specifies the high threshold number of protocol error received from Diameter server that must be met or
exceeded within the polling interval to generate an alert or alarm.
high_thresh
is an integer from 0 through 1000000.
clear low_thresh
Default: 0
Specifies the low threshold number of protocol error received from Diameter server that maintains a
previously generated alarm condition. If the number of errors falls beneath the low threshold within the
polling interval, a clear alarm will be generated.
Specifies the low threshold number of protocol error received from Diameter server that maintains a
previously generated alarm condition. If the number of errors falls beneath the low threshold within the
polling interval, a clear alarm will be generated.
low_thresh
is an integer from 0 through 1000000.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
In the event that the system receives the protocol errors from Diameter server, dcca-protocol-error is
generated.
DCCA protocol error threshold generates alerts or alarms based on the number of protocol error messages
received from Diameter server during the specified polling interval.
generated.
DCCA protocol error threshold generates alerts or alarms based on the number of protocol error messages
received from Diameter server during the specified polling interval.