Release Notes for Cisco Aironet 350, 1100, 1130AG, 1200, and 1230AG Series Access Points for Cisco IOS Release 12.3(4)JA1
OL-8215-01
Installation Notes
WGB Mode on 1200 Series Access Points
This feature allows 1200 series access points to support Work Group Bridge (WGB) functionality on 
either the 802.11b/g or 802.11a radio.
This release does not contain new features. It supports the features introduced in Cisco IOS Release 
12.3(4)JA. Click this link to browse to the release notes for Cisco IOS Release 12.3(4)JA:
Installation Notes
This section contains information you should keep in mind when installing 350, 1100, and 1200 series 
access points.
Installation in Environmental Air Space
This section provides information on installing 1100 and 1200 series access points in environmental air 
space, such as above suspended ceilings.
Cisco Aironet 1100, 1130, and 1200 Series Access Points provide adequate fire resistance and low 
smoke-producing characteristics suitable for operation in a building's environmental air space, such as 
above suspended ceilings, in accordance with Section 300-22(C) of the National Electrical Code (NEC) 
and Sections 2-128, 12-010(3) and 12-100 of the Canadian Electrical Code, Part 1, C22.1.
Caution
The power injector does not provide fire resistance and low smoke-producing characteristics and is not 
intended for use in extremely high or low temperatures or in environmental air spaces such as above 
suspended ceilings.
Note
If you plan to mount a 1200 series access point with a 5-GHz radio in an area subject to environmental 
air space, Cisco recommends that you mount the access point horizontally so that its antennas point 
down. Doing so ensures that the access point complies with regulatory requirements for environmental 
air space with the 5-GHz radio installed. 
Power Considerations
This section describes issues you should consider before applying power to an access point.
Caution
The operational voltage range for 1100 series access points is 24 to 60 VDC, and the nominal voltage is 
48 VDC. Voltage higher than 60 VDC can damage the equipment.
Caution
The nominal voltage for 1200 series access points is 48 VDC, and the access point is operational up to 
60 VDC. Voltage higher than 60 VDC can damage the equipment.