Cisco Cisco ONS 15454 M6 Multiservice Transport Platform (MSTP)

Descargar
Página de 23
Procedure
Step 1
In node view (single-shelf mode) or shelf view (multishelf mode), click the Maintenance > Timing > Source tabs.
Step 2
From the Reference drop-down list for the desired Clock, choose the desired reference.
Step 3
From the Operation drop-down list for the desired Clock, choose one of the following options:
• Manual -This operation commands the node to switch to the reference you have selected if the synchronization status
message (SSM) quality of the reference is not lower than the current timing reference.
• Force-This operation commands the node to switch to the reference you have selected, regardless of the SSM quality
(if the reference is valid).
For information about the Clear option, see the
task.
Note
Step 4
Click Apply next to the timing source.
Step 5
Click Yes in the confirmation dialog box. If the selected timing reference is an acceptable valid reference, the node switches
to the selected timing reference. If the selected timing reference is invalid, a warning dialog box appears. Click OK; the
node will not switch to the new timing reference.
Step 6
Return to your originating procedure (NTP).
DLP-G260 Clear a Manual or Force Switch on a Node Timing Reference
This task clears a Manual or Force switch on a node timing
reference and reverts the timing reference to its provisioned
reference.
Purpose
None
Tools/Equipment
"DLP-G46 Log into CTC" task in
document.
Prerequisite Procedures
As needed
Required/As Needed
Onsite or remote
Onsite/Remote
Maintenance or higher
Security Level