a) Using a cross-over (CAT-5) LAN cable, plug one connector into the MSM port that corresponds to the
TNC/TNCE/TSC/TSCE card in Slot 1 of the subtending ONS 15454 M6 shelf and plug the other end into Port 2 of
the active Catalyst 3560.
b) Using a cross-over (CAT-5) LAN cable, plug one connector into the MSM port that corresponds to the
TNC/TNCE/TSC/TSCE card in Slot 8 and plug the other end into Port 2 of the standby Catalyst 3560.
c) Repeat Steps
21.a, on page 16
and
21.b, on page 16
for each subtending shelf in the multishelf configuration using
Ports 3 through 21 on the Catalyst 3560 switches.
In order to connect the ONS 15454 M6 subtending shelves to the ONS 15454 M6 node controller without using
a catalyst, follow the steps described in “NTP-G308 Connect the ONS 15454 M6 Multishelf Node and the ONS
15454 M6 Subtending Shelves” in the
. To connect an ONS 15454
subtending shelf to the ONS 15454 M6 node controller without using a catalyst switch, connect the MSM ports
that correspond to the TNC/TNCE/TSC/TSCE cards in Slot 1 and Slot 8 of the ONS 15454 M6 node controller
to the ONS 15454 subtending shelf TCC2/TCC2P/TCC3 cards in Slot 7 and Slot 11.
Note
Step 22
Repeat
Step 10, on page 15
through
Step 22, on page 16
for each subtending shelf in the multishelf configuration.
Stop. You have completed this procedure.
NTP-G147 Delete a Passive Unit, Passive Shelf, Shelf, or Rack from a Multishelf
Node
This procedure deletes a passive unit, passive shelf, shelf, or
rack from a multishelf node.
Purpose
None
Tools/Equipment
16