Cisco GainMaker Reverse Segmentable Node - 1GHz with 40 52 MHz Split Referencia técnica
GainMaker Broadband Amplifier Platform
System Amplifier Bypass Housing Closure Information
Closing the Housing
Introduction
This information gives step-by-step instructions on correctly closing the GainMaker
™
Broadband Amplifier Platform System Amplifier Bypass Housing.
Important: For complete information about installing the GainMaker Broadband
Important: For complete information about installing the GainMaker Broadband
Amplifier Platform System Amplifier Bypass Housing housing and amplifier please
refer to the GainMaker Broadband Amplifier Platform System Amplifier Bypass
Housing Installation and Operation Guide, part number 713060.
Tightening the Closure Bolts
To tighten the closure bolts, follow the steps below.
Important: Before you start, make sure you have a torque wrench with a 1/2-in.
Important: Before you start, make sure you have a torque wrench with a 1/2-in.
socket.
CAUTION:
Avoid moisture damage and RF leakage! Follow the procedure
exactly as
shown below to ensure a proper seal.
1.
Inspect the housing gasket and all mating surfaces. Wipe off any dirt and
debris.
2.
Close the housing and finger-tighten all closure bolts.