Chapter 2    Optimize Your System Performance for Downloads and Staging 
 
 
 
58 
4024836 Rev D 
7  Is there enough bandwidth to add the new bootloader carousels? (Bootloader 
carousels require data rates between 1.00 and 3.00 Mbps.) 
 
If yes, go to Verify a VCI for Inband BFS Sources on BFS BIG Systems (on 
page 58). 
 
If no, refer to Recommendations for Data Carousel Rate Management Technical 
Bulletin (part number 716377) for details on how to increase the bandwidth of 
your system. 
 
Verify a VCI for Inband BFS Sources on BFS BIG Systems 
This section describes how to check the number of BFS sessions on your system to 
determine whether any unused VCIs are present for the inband BFS carousel. 
Notes: 
 
Your network was initially installed and reserved with 20 Virtual Channel 
Indicator (VCI) connections (values 256-275) on the ATM switch. The VCIs carry 
inband BFS information from the DNCS to the BIG. Because you will create a 
new inband source, you must make sure that one VCI is available for each 
additional bootloader carousel that you add to the DNCS. 
 
If you need detailed instructions for this procedure, refer to the manual that 
came with your ATM switch. 
Complete the following steps to determine whether there are enough unused VCIs 
available for the additional inband BFS carousels. 
1  Using the manual that came with your ATM switch, check the ATM switch to 
determine the number of unused VCIs. 
2  Are there enough VCIs for the new bootloader carousels? 
 
If yes, go to Add a Bootloader Source to the DNCS (on page 59). 
 
If no, add more VCIs to the switch. Then, go to Add a Bootloader Source to 
the DNCS (on page 59). 
Note: Having unused VCIs does not present any issues to your system; 
therefore, we recommend that you create 5 to 10 extra VCIs.