Attaching the Coaxial Connectors 
 
21 
 
Attaching the Coaxial Connectors 
To Trim the Center Conductor 
The 1.2 GHz GainMaker Amplifier requires pin-type connectors for all RF 
connections. 
Standard pin connectors, with pins extending 1.5 in. to 1.6 in. (3.8 cm to 4.1 cm) from 
the connector shoulder, require no trimming. You must trim longer pins before 
inserting them into the housing. 
Complete the following steps to trim long pins. 
1  Place the connector above the entry port so that it lines up with its installed 
position. 
2  If the center conductor pin extends past the STRIP line on the housing, trim the 
pin flush to the STRIP line. 
The following diagram shows a visual guide of the center conductor trim length. 
 
 
To Connect the Coaxial Cable Pin Connector to the Amplifier Housing 
Complete the following steps to connect the coaxial cable pin connector to the 
amplifier housing. 
1  Begin this procedure with the amplifier housing open. Refer to To Open the 
Amplifier Housing (on page 13). 
2  If the center conductor pin extends beyond the STRIP line on the housing, trim 
the pin with heavy-duty wire cutters. 
3  Insert the appropriate coaxial connector into the housing at the desired housing 
port. Tighten the connector nut according to the manufacturer’s specifications.