Cisco Cisco 1 GHz GainMaker Amplifier Guía De Instalación

Descargar
Página de 124
 
Chapter 2    Installation and Configuration 
 
 
 
28 
 
To Replace the Crowbar Surge Protector 
Note: The crowbar surge protector is installed in factory. This procedure is to replace 
it on site. 
Complete the following steps to install the crowbar surge protector in the amplifier. 
1  Begin this procedure with the housing open. Refer to To Open the Amplifier 
Housing (on page 13). 
2  Remove the amplifier module cover by loosening the amplifier module cover 
screws. 
 
3  Remove the old crowbar surge protector. 
4  Install the new crowbar surge protector in the surge protector slot. Refer to the 
illustration below. 
 
Note: 
 
Make sure that all pins on the crowbar surge protector bottom align with the 
pin holes in the surge protector slot, allowing the surge protector to install flat 
against the amplifier module. 
 
Make sure that the components face the outside of the station (see diagram for 
proper positioning). Heat shrink tubing has been added to prevent shorting. 
5  Replace the amplifier cover and tighten the amplifier cover screws from 10 in-lb 
to 12 in-lb (1.12 Nm to 1.35 Nm).