Cisco Cisco 1 GHz GainMaker Amplifier Guía De Instalación

Descargar
Página de 124
 
 
Closing the Amplifier Housing 
 
39 
 
Closing the Amplifier Housing 
To Close the Amplifier Housing 
Complete the following steps to close the amplifier housing. 
 
CAUTION: 
Avoid moisture damage and RF leakage! Follow the procedure exactly as 
shown below to ensure a proper seal.
 
1  Make sure that the housing gaskets are clean and in the correct position. Wipe off 
any excess dirt and debris. 
2  Close the housing. 
 
CAUTION: 
Ensure that all the cables are out of the way when closing the housing. 
3  Lightly secure the six ½-inch closure bolts with a hex driver or ratchet. 
4  Using a torque wrench, tighten the six closure bolts to 25 in-lb (2.8 Nm). 
Important: Tighten the closure bolts in the correct sequence as specified in 
Torquing Sequence (on page 39). 
5  Using the same pattern, tighten the housing closure bolts from 5 ft-lb to 12 ft-lb 
(6.8 Nm to 16.3 Nm). 
 
Torquing Sequence 
The following diagram shows the proper torquing sequence for the housing closure 
bolts.