Preparing for Forward Path Balancing 
 
45 
 
whose loss characteristics are driven by DC control voltage. 
The position of switch S1 sets the DC control voltage driving the Bode according to 
the setup mode or operational mode required for the station. 
Refer to the following table for more information on choosing the correct switch 
position for your application. 
Note: Consult your system technical supervisor or manager for more information 
about which choice of setup mode to use as this may be dictated by your system or 
corporate engineering policy. 
Switch S1 Position Information for Thermal Configured Stations 
Position 1 
Line extender Only 
Position 2 
NOT USED 
Position 3 
Line Extender and Coax 
A thermistor (thermal) driven 
circuit on the line extender sets 
the DC control voltage that 
drives the Bode. 
This circuit detects the line 
extender’s internal temperature 
and generates the proper level 
of DC control voltage, setting 
the proper loss characteristics of 
the Bode with respect to the 
current outdoor temperature. 
Note:
 This switch position is 
meant to compensate for the 
temperature related level 
variations of the line extender 
only.    This switch position is 
normally selected when 
underground cable precedes the 
station, since such cable is 
subject to little temperature 
variation. 
Important! Do not select this 
position. This position is reserved 
for stations with an AGC 
installed. 
While adjustments to the Manual 
Backoff potentiometer will affect 
line extender gain with S1 in this 
position, once S1 is set to position 
1 or 3, the manual potentiometer 
setting will not affect proper 
thermal line extender operation. 
Leaving the switch in this position 
disables the thermistor (thermal) 
driven circuit and enables the 
backoff potentiometer on the line 
extender. This sets the DC control 
voltage that drives the Bode to a 
constant setting, regardless of the 
current outdoor temperature. 
Note: This is a factory setting used 
to verify proper station gain with 
a given amount of manual gain 
backoff. 
A thermistor (thermal) driven 
circuit on the line extender sets 
the DC control voltage that drives 
the Bode. 
This circuit detects the line 
extender's internal temperature 
and generates the proper level of 
DC control voltage, setting the 
proper loss characteristics of the 
bode with respect to the 
temperature. 
Note:
 This switch position is 
meant to compensate for the 
temperature related level 
variations of both the line 
extender and the coaxial cable 
preceding the station. 
This switch position is normally 
selected when overhead cable 
precedes the station, since such 
cable is subject to temperature 
variation. 
Note: Switch S1 in Position 2, and the backoff potentiometer, are used in AGC stations only. 
 
To Verify the Input Signal Level 
Complete the following steps to test the input signal level. 
Important: You cannot balance the line extender without the proper input signals. 
1  Connect the test equipment to the forward input test point shown in the 
illustration below.