Cisco Cisco 1 GHz GainMaker Amplifier Guía De Instalación

Descargar
Página de 28
GainMaker Amplifier Reverse Switch Removal Instruction Sheet 
748052 Rev C 
System Amplifier Reverse Switch Removal,
 Continued 
Removing the Amplifier Module From the Housing 
Important:  If the system amplifier is located in the field, follow the instructions in 
Disconnecting Power From the System Amplifier before removing the amplifier 
module from the housing. 
Follow these steps to remove the amplifier module from the housing. 
 
1. 
Is the system amplifier housing open? 
• 
If Yes, proceed to step 2. 
• 
If No: 
− 
Use a torque wrench to loosen the six housing bolts in the housing lid. 
− 
Open the housing. 
 
2. 
Unplug the 10-pin keyed connector of the power supply cable from the 
amplifier module.