Cisco Cisco 1 GHz GainMaker Amplifier Guida All'Installazione
6
GainMaker Amplifier Reverse Switch Removal Instruction Sheet
748052 Rev C
System Amplifier Reverse Switch Removal,
Continued
Removing the Amplifier Module From the Housing
Important: If the system amplifier is located in the field, follow the instructions in
Disconnecting Power From the System Amplifier before removing the amplifier
module from the housing.
Follow these steps to remove the amplifier module from the housing.
Follow these steps to remove the amplifier module from the housing.
1.
Is the system amplifier housing open?
•
•
If Yes, proceed to step 2.
•
If No:
−
−
Use a torque wrench to loosen the six housing bolts in the housing lid.
−
Open the housing.
2.
Unplug the 10-pin keyed connector of the power supply cable from the
amplifier module.