Cisco Cisco Network Services Manager 5.0 Referencia técnica
Page 19
OL-28510-02
Nexus 5000
Verify that uplinks and downlink trunks are configured in switchport mode and set to trunk:
od-l1-n5k-b# show running-config int port-channel 5
!Command: show running-config interface port-channel5
!Time: Wed Oct 26 18:28:12 2011
version 5.0(3)N2(2)
interface port-channel5
description UCS fabric interconnect A
switchport mode trunk
vpc 5
switchport trunk allowed vlan 229
spanning-tree port type edge trunk
od-l1-n5k-b# show running-config interface ethernet 1/5
!Command: show running-config interface Ethernet1/5
!Time: Tue Dec 13 18:10:25 2011
version 5.0(3)N2(2)
interface Ethernet1/5
switchport mode trunk
switchport trunk allowed vlan 229
channel-group 5 mode active
od-l1-n5k-b#
If using vPCs, make sure the vPC is up and permits VLANs, as in the following example:
od-l1-n5k-b# show vpc
Legend:
(*) - local vPC is down, forwarding via vPC peer-link
vPC domain id : 7
Peer status : peer adjacency formed ok
vPC keep-alive status : peer is alive
Configuration consistency status: success
Per-vlan consistency status : success
Type-2 consistency status : success
vPC role : primary
Number of vPCs configured : 3
Peer Gateway : Enabled
Dual-active excluded VLANs : -
Graceful Consistency Check : Enabled
vPC Peer-link status
---------------------------------------------------------------------
id Port Status Active vlans
-- ---- ------ --------------------------------------------------
1 Po1 up 1,229