Brother RJ-3050 Guía De Referencia
ESC/P Command Reference
- 74 -
5. Control Command Details
Note
* For parameter numerals 0
–9, both 00h–09h and 30h–39h are recognized.
* The parameter types a, b, c, d, e, f and g are recognized even when uppercase.
*
The parameter “parentheses deletion” is available only when GS1-128 (UCC/EAN-128) is selected.
*
The parameter “ratio between thick and thin bars” is available only when t0, t1 or t9 is selected.
*
The parameter “equalize bar lengths” is available only when t5 or t6 is selected.
* If any other type is selected, these parameters are ignored.
* When there is no type command or an invalid type command has been specified, CODE39 is
specified.
* The number of characters that can be entered for each barcode type is as follows:
t0: 1
–50 characters (“*” is not included)
t1: 1
–64 characters
t5: 7 characters (for EAN-8)
12 characters (for EAN-13)
11 characters (for UPC-A)
11 characters (for UPC-A)
t6: 6 characters
t9: 3
–64 characters (Must begin and end with A, B, C, or D.)
ta: 1
–64 characters
tb: 1
–64 characters
tc: 3
–15 characters (begins with “01”) (except with RSS Expanded)
1
–64 numbers or 1–40 letters* (for RSS Expanded)
* ISO646 characters can be printed.
(numbers, letters, spaces, !, ”, %, &, ’, (, ), *, +, ,, -, ., /, :, ;, <, =, >, ? and _)
(numbers, letters, spaces, !, ”, %, &, ’, (, ), *, +, ,, -, ., /, :, ;, <, =, >, ? and _)
td: 1
–64 characters
te: 5 characters, 9 characters, 11 characters
tf: 2 characters, 5 characters
tg: 1
–14 characters
(2) B or b: Beginning of barcode data
(3) [Barcode data]: Barcode data
? (Generate check digit):
Generates a check digit when
“?” is in the barcode data.
The position of “?” is irrelevant as long as it is within the barcode data.
With POSTNET, CODE93, UPC/EAN EXTENSION, CODE128 and GS1-128(UCC/EAN-128), no
check digit is generated.
If
“?” is inserted, it is treated as barcode data.