Brother RJ-3050 参考指南

下载
页码 129
ESC/P Command Reference 
 
- 74 - 
5. Control Command Details 
Note 
* For parameter numerals 0
–9, both 00h–09h and 30h–39h are recognized. 
* The parameter types a, b, c, d, e, f and g are recognized even when uppercase. 
The parameter “parentheses deletion” is available only when GS1-128 (UCC/EAN-128) is selected. 
The parameter “ratio between thick and thin bars” is available only when t0, t1 or t9 is selected. 
The parameter “equalize bar lengths” is available only when t5 or t6 is selected. 
* If any other type is selected, these parameters are ignored. 
*  When  there  is  no  type  command  or  an  invalid  type  command  has  been  specified,  CODE39  is 
specified. 
* The number of characters that can be entered for each barcode type is as follows: 
t0:  1
–50 characters (“*” is not included) 
t1:  1
–64 characters 
t5:  7 characters (for EAN-8) 
12 characters (for EAN-13) 
11 characters (for UPC-A) 
t6:  6 characters 
t9:  3
–64 characters (Must begin and end with A, B, C, or D.) 
ta:  1
–64 characters 
tb:  1
–64 characters 
tc:  3
–15 characters (begins with “01”) (except with RSS Expanded) 
1
–64 numbers or 1–40 letters* (for RSS Expanded) 
* ISO646 characters can be printed. 
(numbers, letters, spaces, !, ”, %, &, ’, (, ), *, +, ,, -, ., /, :, ;, <, =, >, ? and _) 
td:  1
–64 characters 
te:  5 characters, 9 characters, 11 characters 
tf:  2 characters, 5 characters 
tg:  1
–14 characters 
 
(2) B or b:    Beginning of barcode data 
 
(3) [Barcode data]:    Barcode data 
? (Generate check digit): 
Generates a check digit when 
“?” is in the barcode data. 
The position of “?” is irrelevant as long as it is within the barcode data. 
With POSTNET, CODE93, UPC/EAN EXTENSION, CODE128 and GS1-128(UCC/EAN-128), no 
check digit is generated. 
If 
“?” is inserted, it is treated as barcode data.