Fixing the installation plate
B
A
D
C
D
You can select the direction of the drain hose depending on where you want to 
install the indoor unit. Therefore before  xing the installation plate to a wall or a 
window frame, you must determine the position of the 65mm hole through which 
the cable, pipe and hose pass to connect the indoor unit to the outdoor unit. 
When facing the wall, the pipe and cable can be connected from the: 
 
-
  Right (A)
 
-   Left (B)
 
-   Underside_right (C)
 
-   Rear_right or left (D)
1
Determine the position of the pipe and drain hose hole as seen in the picture 
and drill the hole with an inner diameter of 65mm so that it slants slightly 
downwards. 
CAUTION   Make sure to drill only one hole after choosing the direction of 
the pipe. 
2
Fix the indoor unit.
If y
x the indoor unit on a wall
(1) Fix the installation plate to the wall giving attention to the weight of the 
indoor unit. 
Note
 
 If you mount the plate to a concrete wall using plastic 
anchors, make sure that gaps between the wall and the plate, 
created by projected anchor, is less than 20 mm. 
Wall
<20 mm
Plastic Anchor
If y
x the indoor unit on a window frame
(1) Determine the positions of the wooden uprights to be attached to the 
window frame. 
(2) Attach the wooden uprights to the window frame giving attention to 
the weight of the indoor unit.
(3) Attach the installation plate to the wooden upright using tapping 
screws.
Direction of pipe
Unscrew the caps at the end of each pipe.
Result:
All inert gas exhausts from the indoor unit.
Unscrew the caps
Pipes
Purging the Indoor Unit
•  Fix the installation plate without inclining to one side.
•   Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not 
strong enough to withstand the product weight, the unit could fall and cause injury.
•   The remaining air in the Refrigeration cycle, which contains moisture, 
may cause malfunction on the compressor.
•   Always contact the service center or a professional installation agency 
for product installation.
•   To prevent dirt or foreign substances from getting into the pipes during 
installation, do NOT remove the caps completely until you are ready to 
connect the pipes.
170
85
47
(Unit : mm)
Pipe hole 
(Ø65mm)
120
72
68
72
(Unit : mm)
Pipe hole 
(Ø65mm)
**18U*P , **24 **
75
72
55
72
(Unit : mm)
Pipe hole 
(Ø65mm)
**09U*P ,**12** ,**18U**Q
**09U**Q