AMC pm-scc-80 am Manual De Usuario

Descargar
Página de 45
charging, reduce loads, or expand the PV array to ensure that batteries are fully 
recharged. For maximum service life batteries should be fully recharged at least 
once every five to ten days. 
 
G-03: Set Day LOG# (1-90) 
 
z  Use G-03 to set the Day Log number to display the energy harvested from PV 
array (shown in G-04 and G-05) by Premium MPPT Series over a period of time.   
 
z  If it is selected as #2 displays past power production since the last power cycle 
(or up to 90 days previous) along with the date of day before the current date.   
Use UP and DOWN keys to select the date by one and the energy harvested on 
the date shown is displayed in G-04.   
 
G-04: Day LOG#  :kWHr 
 
z  This screen displays how much the solar energy was harvested in kWHr and AHr 
according to the selected day shown in G-03.   
 
G-05: Day LOG#  @FLOAT 
 
z  This screen displays how much time the charger was in Float mode according to 
the selected day shown in G-03.   
 
G-07: Average Last   Days 
xxxxx kWHr xxxx AHr 
 
z  This screen shows the average power produced over the past cumulative days as 
both in kWHr and AHr.   
 
G-08: Average Last   Days 
          FLOAT xx : xx 
 
z  This screen displays how much average time the charger was in Float mode in 
the past cumulative days, shown in Hour: Minute.   
 
G-09: Clear Energy Harvest 
 
z  Use Constant G-09 to clear Today’s Data or all the Logged Data. 
 
5-15