Chapter 6 Trouble Shooting 
 
z  Proceed as follows for a quick detection of common faults. 
z  Consult your Power Master dealer if the fault cannot be resolved. 
 
Problem or Error message 
Cause 
Solution 
 
 
 
 
When the PV array voltage is 
higher than 140VDC for 
PM-SCC-80AM or higher than 
240VDC for PM-SCC-80AMW, 
the battery charging stops. 
Make sure the PV array 
voltage is within the 
rated voltage range. 
 
 
 
 
The ambient temperature is too 
high and it causes the over 
temperature of heatsink. 
Place the Premium 
MPPT Series unit in a 
cool and well-ventilated 
room. 
 
 
 
 
The battery temperature is 
detected too high by the Battery 
Temperature Sensor (BTS-3). 
Check the battery 
condition and place the 
battery bank in an 
well-ventilated room. 
 
 
 
 
The communication failure 
between Master and Slave units 
or between Slave and Slave units 
has occurred. 
Check the connecting 
cables between Master 
and Slave units or the 
cables among Slaves.   
ERROR!!! 
High Input Voltage 
ERROR!!! 
Premium MPPT Over-Temp. 
ERROR!!! 
Battery Over-Temp. 
ERROR!!! 
Parallel COM Failed   
 
 
6-1