AMC pm-scc-80 am Manual De Usuario
Chapter 6 Trouble Shooting
z Proceed as follows for a quick detection of common faults.
z Consult your Power Master dealer if the fault cannot be resolved.
z Consult your Power Master dealer if the fault cannot be resolved.
Problem or Error message
Cause
Solution
When the PV array voltage is
higher than 140VDC for
PM-SCC-80AM or higher than
240VDC for PM-SCC-80AMW,
the battery charging stops.
Make sure the PV array
voltage is within the
rated voltage range.
The ambient temperature is too
high and it causes the over
temperature of heatsink.
Place the Premium
MPPT Series unit in a
cool and well-ventilated
room.
The battery temperature is
detected too high by the Battery
Temperature Sensor (BTS-3).
Check the battery
condition and place the
battery bank in an
well-ventilated room.
The communication failure
between Master and Slave units
or between Slave and Slave units
has occurred.
Check the connecting
cables between Master
and Slave units or the
cables among Slaves.
ERROR!!!
High Input Voltage
ERROR!!!
Premium MPPT Over-Temp.
ERROR!!!
Battery Over-Temp.
ERROR!!!
Parallel COM Failed
6-1