Component identification  82 
HP Systems Insight 
Display LED color 
Internal system 
health LED color 
Status 
PPM failure, slot X 
(amber) 
Red 
One or more of the following conditions may exist: 
 
PPM in slot X has failed. 
 
PPM is not installed in slot X, but the corresponding 
processor is installed. 
DIMM failure, slot X 
(amber) 
Red 
One or more of the following conditions may exist: 
 
DIMM in slot X has failed. 
 
DIMM has experienced a multi-bit error. 
   
 Amber 
One or more of the following conditions may exist: 
 
DIMM in slot X has reached single-bit correctable 
error threshold. 
 
DIMM in slot X is in a pre-failure condition. 
DIMM bank error (all 
slots in one bank, 
amber) 
Red 
One or more of the following conditions may exist: 
 
The bank is not populated entirely. 
 
All DIMMs in the bank do not match. 
 
Memory riser board is missing or not fully seated. 
DIMM failure (all 
slots, amber) 
Red 
One or more of the following conditions may exist: 
 
No valid or usable memory is installed in the system. 
 
The banks are not populated in the correct order. 
Overtemperature alert 
(amber) 
Red 
System temperature has exceeded OS cautionary level or 
critical hardware level.  
Fan (amber) 
Red 
A required fan has failed. 
 
Amber 
A redundant fan has failed. 
 
 
SAS and SATA device numbers 
The server supports a combination of up to 16 SAS and SATA hard drives in two hard drive cages.  